ÖkoFEN Pellematic PES 32 details
Back to burner list
| Appliance name |
ÖkoFEN Pellematic PES 32 |
| Situation |
Freestanding |
| Fuel type |
Pellets |
| Emission |
7.3 mg/MJ |
| Emission factor |
0.13 g/kg |
| Efficiency |
88 % |
| Water heater |
None |
| Approval number |
231551 |
Conditions
- Only pelletised wood fuel meeting the following specifications shall be used:
- Fines: 1% maximum through a 3 mm screen;
- Bulk density: 640 kilograms per cubic metre minimum;
- Size: 10 mm maximum diameter and 38 mm maximum length;
- Ash content: 1.0% maximum (dry basis);
- Moisture Content: 4% to 9% (dry basis); and
- Heat content: 18 MJ/kg to 21 MJ/kg (dry basis).
- The pelletised wood fuel shall comprise only sawdust and/or wood-shavings from wood that has not been treated with any chemicals except non-chlorinated anti-sapstain chemicals.
- The appliance shall be operated at all times in accordance with the "Installation and Operating Instructions" supplied with each appliance.
- A permanent label shall be attached to each appliance in a position that is readily visible after installation. The labels shall contain the following information:
- The manufacturer of the appliance (OkoFEN);
- The unique model name (Pellematic PES 32);
- The unique serial number of the appliance;
- The number of the test report in which the appliance is described (K 2471 2018 T1);
- The authorisation number (231551);
- The approved fuel for use in the heater (pellets);
- The measured (average) particulate emission rate in grams per kilogram (0.13 g/kg);
- The measured emission rate per unit of useful heat output (7.3 mg/MJ);
- The percentage measure of thermal efficiency (88%);
- The range of heat outputs tested (9.6 kW – 31.2 kW);
- The statement "Performance may vary from test values depending on the actual operating conditions"; and
- Space to allow the installer to place the date of installation.